K5 SYSTEMTechnical guide 2012
Page 10K5 System Technical GuideChapter 1Chapter 1 K5 System OverviewK5 System Overview 1.1 System Description ...
Page 100K5 System Technical Guide3. A window will pop up for IP address setting. Modify IP address, but remember to leave the Mask and Gate as it is,
Page 101K5 System Technical Guide5.2.3§IP§Address§Setup§by§IP§Device§SowareAn IP setup tool has been inserted in IP Device software. The function is
Page 102K5 System Technical Guide5.2.3.3§Set§IP§Address1. Start IP Device software2. Right click on K5 System, then select IP Node Cong in the pop-
Page 103K5 System Technical Guide4. Then it will pop up a window to show devices that are detected. Assume that 192.168.0.80 is the device that is s
Page 104K5 System Technical Guide6. A window will be pop up to inform you if cong succeed, just like the following picture shows. Press ‘OK’ to con
Page 105K5 System Technical Guide •Check the information, then Click Login to access IP Device.File: Include Change and Password and Exit.Language: In
Page 106K5 System Technical Guide5.3.3§Project§Property • Right click on Default Project, then it will pop up a menu. Select Project Property • It wil
Page 107K5 System Technical GuideIP Seg: Select a IP Segment for the new project. Note that all the IP address must be in the same segment.We will tak
Page 108K5 System Technical GuideModel DescriptionFor example, in K5 System, see the table, IP Nodes can be congured like the following pictureModel
Page 109K5 System Technical GuideAfter adding the devices to the project, Click on Save to exit. Also, if all the decivices are installed in the syste
Page 11K5 System Technical Guide§§ 1.1§System§DescriponThe K5 system is the ideal system for simplifying installation in residential compounds with a
Page 110K5 System Technical GuideIf you want to check if the devices are online, you can press Refresh Online button or click right mouse button on K5
Page 111K5 System Technical GuideAssuming that we have that 4 door stations and 8 monitors in each block. And door staions coded from 1~4; monitors co
Page 112K5 System Technical GuideWe can use Add or Batch Add to add monitors. Add is to add monitors one by one, while Batch Add enables you to add mo
Page 113K5 System Technical Guide •Extended Monitor Conguration Maximum 3 monitors can be set in one apartment. One of them is Master and the other 2
Page 114K5 System Technical GuideGuard Center Priority: When block givs out call, to set how the calll is transferred to dif-ferent switch boardsEven
Page 115K5 System Technical Guide5.3.6.2§Event§up§Seng§Event here has to do with the monitors. Events such as defense-enabling/disabling, emergency c
Page 116K5 System Technical GuideHere please note that:1. Switch can call any of the devices directly by their name.2. Common door stations can
Page 117K5 System Technical Guide5.3.7§Management§of§Block§C5-IPCThe management of C5-IPC provides access to all the parameters of a C5-IPC, the diffe
Page 118K5 System Technical Guide1. Local Call Table: To make namelist for the monitors in-side the block. The door sta-tion can input the specified n
Page 119K5 System Technical GuideHere we can choose to Use Project Default, refer to previous chapter Default project parameters. Or we can untick the
Page 12K5 System Technical Guide§§ 1.2§System§Features • Max. 512 apartments per block • Max.8 door stations per block • Max 3 monitors in one at • M
Page 120K5 System Technical GuideGL Call IM: To set Prior-ity for Switchboard call-ing indoor monitor.GL Call DS: To set Pri-ority for Switchboard ca
Page 121K5 System Technical Guide3) Event upEvent up setting decides which switchboard should the alarm and events be sent to. We can adopt the defaul
Page 122K5 System Technical Guide5) MonitorMonitor Switch Timer: Set the time duration of each port when do monitoring on the monitorMonitor 1~8: Se
Page 123K5 System Technical Guide7) Dip StatuesThis information is uploaded from C5-IPC device DIP switch setting; it just can be changed on C5-IPC. F
Page 124K5 System Technical Guide5.3.8.1§Call§TableCommon Call Table: See Input Table in 5.3.6.IP Call Table: See IP Call Table in 5.3.6.Call pri
Page 125K5 System Technical Guide •IP8210 controlThis item is reserved, don’t change the set-ting easily •Call Table QuanRows of Common Call Tabl
Page 126K5 System Technical Guide2) Press the PA key of the related C5-IPC, A window will pop up showing the IP address of the C5-IPC.§§ 5.4§IP§Agent
Page 127K5 System Technical Guide3. Enter the Server name and Database Name Server name: machine name + ‘\K2012’ Database Name: K2012It is
Page 128K5 System Technical Guide115234 5 6 7 8 9 10 11 12 13 14Item Description1. S/W Title Bar Display the name of the software2. ID Shows the user
Page 129K5 System Technical GuideItem Description1. Device List Consists of 4 parts: GL & PC, DS & CDS, Monitor & Camera2. Call List Call
Page 13K5 System Technical Guide§§ 1.3§System§ApplicaonsLarge residential compoundOne of the advanced features of K5 intercom system is that it suppo
Page 130K5 System Technical GuideItem Description1. Monitor Time Displays the monitor time elapsed2. Device Name Displays the name of the monitored de
Page 131K5 System Technical Guide5.4.4.4§Device§ListDevice List consists of 4 parts, including GL & PC, DS & CDS, Monitor and Camera. After de
Page 132K5 System Technical Guide •DS & CDSAll the door stations & common door stations are listed in this frame. You can input full or part o
Page 133K5 System Technical Guide2) Incoming Call3) MonitorPress button to monitor the related DS or CDS. The video will be shown in the focused mon
Page 134K5 System Technical Guide 2) Incoming Call1) Call and wait for picking up1) Press Accept to enter talking status, else press Refuse to deny th
Page 135K5 System Technical Guide •Call ListClick the Call List tab to unfold the lists. Call List is a record that includes call destination/call sou
Page 136K5 System Technical Guide5.4.5.2§Name§&§Funcon§in§The§Record§Window21Item Description1. Record List Includes audio record, video record a
Page 137K5 System Technical GuideIcons & Description1. (All Record): All record including audio record, video record and talk record2. (Audio R
Page 138K5 System Technical Guide5.4.6§Capture§Viewer1452 3Item DescriptionCaptured Picture List Click to select the specic pictureRecord Filter Filt
Page 139K5 System Technical GuideBROWSE MODE BIG PICTURE MODEIf you want to back to BROWSE MODE, just double click on one picture in the video screen.
Page 14K5 System Technical GuideChapter 2K5 System PartsChapter 2 K5 System Parts2.1 Wiring Diagram ...
Page 140K5 System Technical Guide Title OSDTime: Show time in video window when monitoring or callingName: Show device name in video window when monit
Page 141K5 System Technical Guide Region NameEach of the 8 alarm regions can be set to its name. And when alarm trigger, the IP-Agent will show the na
Page 142K5 System Technical Guide Channel On Start : Layout: To set initial aspect ratio for video screen when IP-Agent gets start Channel Number: To
Page 143K5 System Technical Guide5.4.7.4§HandsetHandset: Add one handset to IP-Agent Use handset: Enable a handsetCom Port: Select related com port f
Page 144K5 System Technical Guide§§ 5.5§IP§Access§20125.5.1§IntroduconIP Access 2012 is responsible for the maintenance and management of access cont
Page 145K5 System Technical Guide- The default password can be exposed to a hacking thread so it is recommended to change the password by IP-Admin sof
Page 146K5 System Technical Guide5.5.3§Access§Device§ConsoleClick on Access Device Console into setting interface, just like the following picture sho
Page 147K5 System Technical GuideNot Downloaded Cards: Cards that have been inputted into database in PC but haven't been downloaded to the relat
Page 148K5 System Technical GuideProperty: The device information, include device address, hardware versions, software version and timer. Just like t
Page 149K5 System Technical Guide5. Set clock: Synchronize the device time by PC time 6. Set pass rule: Set pass rule for device.( Retails refer to se
Page 15K5 System Technical Guide§§ 2.1§Wiring§DiagramThe below diagram demonstrates what the K5 system can do, by all the connecting different de-vice
Page 150K5 System Technical Guide5.5.4§Card§Console§Click Card Console into setting interface, just like the following picture shows.5.5.4.1§BrowseDis
Page 151K5 System Technical GuideFill the text boxes with card info in the Card Information frame.Card NO: Two methods:1) Inputted Card NO by keyboard
Page 152K5 System Technical GuideClick Filter item, It will pop up a window, just like the right picture shows.Record Count: Choose the max number of
Page 153K5 System Technical GuideAuth +: Add the selected card to other authorized C5-IPCRe Auth: The selected card will be diverted to other authoriz
Page 154K5 System Technical GuideClick Save, set Rule 1 success. Rule 2 ~ Rule 6 settings refers to above-mentioned operation.If you want to download
Page 155K5 System Technical GuideClick Print to print report card, click Export to export a report document.
The technical guide will be changed without notice. Right to interpret and copyright will be reserved(2012.06)
Page 16K5 System Technical Guide§§ 2.2§Product§ListItem Model Mounting Dimensions(mm)ConsumptionStandby WorkingDOOR STA-TIONIP-MR18 Flush Mount 350*12
Page 17K5 System Technical Guide§§ 2.3§System§Parts2.3.1§Outdoor§Staon:§IP-MR18Full aluminum panel with luxurious and elegant appearance, design with
Page 18K5 System Technical Guide1. Camera Lens: Capture images2. Night View LED: Compensate light3. Speaker: Conversation between visitors and users4.
Page 19K5 System Technical Guide2.3.1.4§§Door§Staon§FunconsDigital call by visitorsA visitor can input the resident’s room number to be shown on the
Page 2K5 System Technical GuideSYSTEM FEAGUTESPRODUCT FEAGUTESLarge capacity Simple installationSignal isolutionMenu Guide Intercom Picture Memory Mul
Page 20K5 System Technical Guide2.3.2§Indoor§Monitor:§C5-AT27With 7” digital TFT touch screen and touch sensor button, this monitor is the best choice
Page 21K5 System Technical Guide1. LCD screen: Display the images from outdoor station. Touch operation2. LED indicator: Normally light on when in use
Page 22K5 System Technical Guide2.3.2.4§§Indoor§Monitor§FunconsReceiving callsCall from door station: When the monitor rings, it means a call is comi
Page 23K5 System Technical Guide2.3.3§Switchboard:§IP-G21IP-G21 is the advanced Switchboard for K5 system, designed as a dedicated switchboard to sup-
Page 24K5 System Technical Guide1. LCD screen: Display the icon menu and images ,touch operation2. Microphone: Receives sound from the user3. Alarm Bu
Page 25K5 System Technical Guide2.3.3.3§SpecicaonPower input: DC 24VStandby Current: 390mAWorking Current: 850mAScreen:
Page 26K5 System Technical Guide •LINK: Signal indicator. Flicker means signal is transmitted in bus •Power: Power indicator. Always ON •IN-USE: Stat
Page 27K5 System Technical Guideconnected to next distributor •PORT-A, PORT-B, PORT-C, PORT-D: 4 output, it can be connected to indoor monitors •VD-SE
Page 28K5 System Technical GuideSpecicationsPower supply: DC24VStandby current: 60mAWorking current: 120mAWorking temperature:
Page 29K5 System Technical Guidestation only •JWB (OUT): Bus Signal Output. RJ45 port includes audio, data & video. It can be connected to distrib
Page 3K5 System Technical GuideChapter 1: K5 System Overview ...101.1 System Description ...
Page 30K5 System Technical Guide •JWP: Power input. P+, positive 24V; P-, negative. •JWB (IN1, IN2, IN3, IN4): Connected to door stations (Max.4). •PA
Page 31K5 System Technical Guide •PA204: Reserved in normal status, for door station communication in test status •LED201: Power indicator •LED202: Re
Page 32K5 System Technical Guide •LED1: Indicators for rst group of card reader •LED2: Indicators for second group of card reader •JWP: Power input,
Page 33K5 System Technical Guide • Maximum 4 cameras can be connected to the CM-IPCParts and functions •JWP: Power input •JWV: Video signal input •JW/
Page 34K5 System Technical GuideSpecication • Input Voltage: AC 100~120V (2.5A), 200-240V (1.5A) • Input Frequency: 50~60Hz • Rated Volta
Page 35K5 System Technical GuideChapter 3K5 SYSTEM CONFIGURATION3.1 One Entrance without Network ... 363
Page 36K5 System Technical Guide§§ 3.1§One§Entrance§without§NetworkThis is the most basic installation, it applies to buildings where there is only on
Page 37K5 System Technical Guide§§ 3.2§Mul§Entrances§without§NetworkIt applies to the installation where there is more than one entrance in the build
Page 38K5 System Technical Guide§§ 3.3§One§Entrance§with§NetworkNetwork connection is required when communication between different buildings or betwe
Page 39K5 System Technical Guide§§ 3.4§Mul§Entrances§with§NetworkIt applies to the installation where there is more than one entrance in the building
Page 4K5 System Technical Guide2.3.3.3 Specication ...252.3.4 Accessories ...
Page 40K5 System Technical GuideChapter 4K5 SYSTEM SETTINGSChapter 4 K5 System Settings4.1 Door station Setting ...
Page 41K5 System Technical Guide§§ 4.1§Door§staon§Seng4.1.1§Door§staon§working§modeDoor station is to be installed in the entrance, to communicate
Page 42K5 System Technical Guide4.1.2.2§Program§Menu§overview • Enter debug mode to over view all the menus and ToolsDebug State Menu Item Submenu[1]
Page 43K5 System Technical Guide4.1.2.3§Basic§program§sengs • Installer Setup (Debug State->1.Installer Setup)Item Descriptions Factory Set1. DS S
Page 44K5 System Technical Guide • Parameters(Debug State->1. Installer Setup->7. Parameters)Three pages are available inside the parameters, pr
Page 45K5 System Technical Guide • Setup (Debug State->2. Setup)Table 3Item Descriptions Factory Set1. LanguageWhen Several languages are available
Page 46K5 System Technical Guide • Monitor Program (Debug State->3. Monitor Program).Access Monitor Program in Debug Mode (Also See 1.1, Access Mon
Page 47K5 System Technical GuideEnter Delete by Card;Swipe the card to be deleted, and card number and Room Code will be shown after de-letedEnter Del
Page 48K5 System Technical Guide1. Volume AdjustDoor station can adjust its talking volume by keypad. Note that the volume adjusting function is autom
Page 49K5 System Technical Guide4.1.3§§Conguraon§IP-MR18LDoor stations also can work in Normal mode and Debug mode.4.1.3.1§§How§to§enter§debug§modeW
Page 5K5 System Technical Guide3.4.1 Layout ...393.4.2 List of Accessories ...
Page 50K5 System Technical Guide4.1.3.3§Basic§program§sengs • Installer Setup (Debug State->1#->1.Installer Setup)Item Descriptions Factory Set
Page 51K5 System Technical Guide • Installer Setup (Debug State->1#->1. Installer Setup->7. Parameters)Three pages are available inside the p
Page 52K5 System Technical Guide • Setup (Debug State->1#->2. Setup)Table 3Item Descriptions Factory Set1. Language To choose dierent languages
Page 53K5 System Technical Guide • Unlock by code(Debug State->1#->1. Installer Setup->7. Parameters) • Unlock code setting (Debug State->
Page 54K5 System Technical Guide1 . I D C o d e [ 0 - 1 1 ] 2 . U n l o c k T i m i n g [ 0 1 ] 3 . U n
Page 55K5 System Technical GuideEnter Add Card menu, and Room Code is asked.Input Room Code Read the card to be authorized1 . A d d C a r d . .
Page 56K5 System Technical Guide5 . F o r m a t* Back # SavePlease Input Password[ - - - - - - - - ]5 . F o r m a t* Back # SavePlease Input Passw
Page 57K5 System Technical Guide1. Volume AdjustDoor Station has the advanced feature that conversation vol-ume of both directions can be adjusted in
Page 58K5 System Technical Guide4. Online Monitors searchFunction: Search the certain range of Monitor which is for checking the information of the o
Page 59K5 System Technical Guide§§ 4.2§Lock§Connecon4.2.1§Lock§TypeThe door station can connect two kinds of lock: The power-on to unlock type: The l
Page 6K5 System Technical Guide4.3.3 Address Setting with door station ...684.4 C5-IPC Setting...
Page 60K5 System Technical GuideLOCK PS51 2 36547 8 9#0*RF CARDCN1CN2CN-LKJ/KMBJP-LKBusEB+EB-N.OLK+LK-+12V123T/R-T/R+IP-MR18AC+-+-To C5-IPC or Distri
Page 61K5 System Technical GuideInside callA call made from the unit door station is the inside call, the inside call can only call the monitor inside
Page 62K5 System Technical Guide2) Touch the User Setup icon to enter setup interface, password will be required, Input 2412 + to get access to th
Page 63K5 System Technical Guide2) When it shows the calendar, press the menu button again • C5-AT161) In Standby Mode, Press the menu button on the
Page 64K5 System Technical Guide3) Now navigate to the Setup and press menu button to enter setup pageDoor Station Tone -- 01Door Bell Tone
Page 65K5 System Technical Guide5) Go to Room Address… Alarm In/Out Delay -- 40Date And Time Set ... Room Address...Other Settings...Inf
Page 66K5 System Technical Guide2) In the Calendar page, press the menu again to enter main menu • C5-AT251) In standby mode, press the Menu button03
Page 67K5 System Technical Guide3) Press the button to entry About pageExitH/W : T3-753 a1.2 S/W:
Page 68K5 System Technical Guide5) Now Set the new room address for the monitor navigation button, and press menu button to save the setting Code Num
Page 69K5 System Technical GuideStep2: Activate call function on monitor •C5-ATT27 •C5-AT16 •C5-AT25Press Menu button twice to entry main pagePress Ca
Page 7K5 System Technical Guide4.6.2.1 Connection Schematic ...874.6.3 Access control-GP-ACS ...
Page 70K5 System Technical GuideStep3: Upload Monitor Address(Monitor Code)=== Monitor Program === Old M. code [ 0099 ] New M. code [ - - - -
Page 71K5 System Technical GuideDistributor type SW1 settingC5-F4C5-F422C5-F414F4/F4DV/F4QF4/F4DV/F4QF4/F4DV/F4Q4.4.2.2§DIP§switch§sengS1 is a 6-bit
Page 72K5 System Technical Guide4.4.2.3§IP§Address§SengC5-IPC must be specified an IP address in the network system. And every specified IP address m
Page 73K5 System Technical Guide3. Search the connected C5-IPCClick Search... to start searching the connected C5-IPC4. Cong IP addressSelect the D
Page 74K5 System Technical GuideNOTE:192.168.0.1 & 192.168.0.255 cannot be used by any device in the network.192.168.0.1192.168.0.255 • IP address
Page 75K5 System Technical Guide4.4.2.4§Parameters§SengsAll the parameters of C5-IPC can be set through IP-Device. See IP-Device manual for detail.4.
Page 76K5 System Technical Guide4.4.2.6§Examples:Work with C5-F4 C5-F4C5-F412341R 2WGD VD T/R+ T/R- Z1 Z2 Z3 Z4 COM COM PR3Y4BFV+FV- P- AU P- P+
Page 77K5 System Technical GuideWork with C5-F422 1234C5-AT27PS51 2 3654789#0*RF CARDCN1 CN2CN-LKJ/KMBJP-LKBusEB+EB-N.OLK+LK-+12V123T/R- T/R+123SW1
Page 78K5 System Technical GuideWork with C5-F414Note:1. SW1 need to be set to F4Q position to match with C5-F414.2. S1 need to be set correctly, Bi
Page 79K5 System Technical GuideWork with C5-MDSThis example contains the full function available in the system:Multi entrances with C5-MDS; Monitor d
Page 8K5 System Technical Guide5.3.6.2 Event up Setting ...1155.3.6.3 Input table ...
Page 80K5 System Technical GuideWork with Common Door StationDoor station can be set to function as common door station, being able to call all the mo
Page 81K5 System Technical GuideC5-MDS is used where there are more than one door stations in one block, to serve as door station switch, to separate
Page 82K5 System Technical GuideDIP1 DIP2 C5-MDS Address OFF OFF The rst C5-MDSON OFF The second C5-MDSOFF ON The third C5-MDSON ON The fourth C5-MD
Page 83K5 System Technical Guide4.5.3§Connecon§SchemacWith two C5-MDS in the systemJWB(IN4)P-P+P-P+PAS11ON DIP2 3 4 5 6JWB(IN3) JWB(IN2) JWB(IN1) JW
Page 84K5 System Technical Guide4.6.1§DistributorDistributors serves as a branch, they are connected in hand-in –hand-out style in the BUS(BUS comes o
Page 85K5 System Technical Guide •Distributor to C5-IPC 1234C5-AT27PS51 2 3654789#0*RF CARDCN1 CN2CN-LKJ/KMBJP-LKBusEB+EB-N.OLK+LK-+12V123T/R- T/R+
Page 86K5 System Technical Guide4.6.1.2§Distributor§TypesThere are 3 types of distributors in the system: C5-F411, C5-F422 and C5-F414.C5-F411Power th
Page 87K5 System Technical Guide •Large Capacity: The C5-IMC can save up to 800 pieces of pictures •Flexible time setting: When browsing the pictures
Page 88K5 System Technical Guide4.6.3§Access§control-GP-ACSGP-ACS is access controller. It can work as a standalone access controller or work with C5-
Page 89K5 System Technical Guide4.6.4§Camera§control-CM-IPCCM-IPC is a device designed for Network camera. Through the CM-IPC, the computer can displa
Page 9K5 System Technical Guide5.4.5.3 Record List ... 1365.4.6 Capture Viewer ...
Page 90K5 System Technical GuideChapter 5K5 SYSTEM SOFTWARESChapter 5 K5 System Softwares5.1 PC Station Installation ...
Page 91K5 System Technical Guide5.4.7 Setting ... 1395.5 IP Access 2012 ...
Page 92K5 System Technical Guide§§ 5.1§PC§Staon§Installaon1. Double Click Setup.exe. Start to install PC Station.2. Select language, and then clic
Page 93K5 System Technical Guide3. Click Next4. Select folder for installation, then click next
Page 94K5 System Technical Guide5. Click Install button to begin the installation, then waiting till installation nishes.6. Then click Finish butto
Page 95K5 System Technical Guide7. Please note the default login info:ID: DevicePassword: 123456Server Name: Machine Name + ‘\K2012’Database Name: K2
Page 96K5 System Technical Guide§§ 5.2§IP§Address§SetupFor constructing a DEDICATED LAN for IP system, all network devices must be set to different IP
Page 97K5 System Technical Guide2. Press icon in the notication area. It will pop up a window for setting network.3. Press Properties button in
Page 98K5 System Technical Guide5.2.2.2§Connect§device§to§PC§directly§or§networkThe following is a diagram of direct connection:5.2.2.3§IP8210§Cong§S
Page 99K5 System Technical Guide1. Press Search… button to search the device. You can press Stop button to end the search after the device has been d
Kommentare zu diesen Handbüchern